![]() ![]() Be sure that the pump electrical power switch is in the ON position. ![]() If you have not already done so, you should determine that you have electrical power at the pump. Confirm that the pump electrical power is on ![]() If you can't find the main water shutoff valve for your systemĢ. Typically that's a pressure of 20 or 30 psi. Then turn on water in the building and watch for a pressure drop at the pressure gauge - as pressure falls below the control switch CUT-IN setting, the water pump should turn on. Confirm that water into the building is turned onĬheck that there is no shutoff valve in the OFF position (off is fully clockwise) between the water supply and the building water piping. Water Pump Won't Start - If the Water Pump is Not Turning ON Try These Steps: